Fire Alarm
MENU
Mictron 9900 Main System
The Mictron 9900 analog addressable fire alarm system is suitable for simple to complex installations, it can interface up to 16 loops in a single cabinet.
Each loop can interface up to 126 series AX detectors & devices.
Each loop can interface up to 126 series AX detectors & devices.
Features:
- From 1 to 16 loops
- Hard or soft devices addressing
- LCD based fire zone display
- Built-in 10A power supply/charger
AX-9SL Optical Smoke Detector
- Dual LED alarm indicators for 360º viewing angle.
- Advance sensor logic circuit with analog convector for smoke level discrimination algorithms
- Unique sensing chamber for smoke detection, with wire mesh for protection against dirt, dust and flying insects
- Built-in remote LED (Light Emitting Diode) driver
AX-9HL ROR & FT Heat Detector
- Rate of Rise (ROR) & Fixed Temperature heat detector.
- Dual LED alarm indicators for 360º viewing angle.
- Built-in output circuit to drive external LED indicator.
- Electronic thermistor sensor is use for long term accuracy & reliability.
AX-9SCi Loop Line Short Circuit Isolator
- Isolator base fully compatible with standard AX smoke/heat detector base
- Built-in LED indicators for normal & isolated conditions
- Automatically reset when the loop line returned to normal
AX-9BG Break Glass
- Red LED alarm indicator when glass is shattered
- Unique Alarm/Reset test tool for easy maintenance
- Optional protective clear plastic cover for double action alarm activation
AXM-1ZV-A 1 Zone & 1 Output I/O Unit
- Designed for 1 sounder/control output and 1 flow switch zone input.
- Small & compact design for easy installation
- Housed in a robust casing for added protection, suitable for indoor & outdoor installation.
AXM-1ZV-B 4 Status Input I/O Unit
- Designed for 4 unsupervised inputs or 1 supervised input & 3 unsupervised inputs.
- Compact design for directly integrated into the panel to be interfaced.
- Suitable for monitoring of pump, CO2 panel, valve input as well as 1 zone input.
Optional Sub-System
M9900-LED-R1 The LED based Repeater is also part of the main system, the LED will indicate the alarm, fault & disabled status of the zone
M9900-Mimic-R2 The multi-colour mimic panel consists of all floor plans and section of the building on perspex sheet, the LEDs on mimic floor plans will indicate the location of each fire zone.
M9900-LCD-R3 The LCD based Repeater is used to indicate device & zone information on the LCD display.
M9900-SFAP-R4 The sub-panel (Sub Fire Alarm Panel) can be part of main system, but located away from the main panel, it has the addressable devices connected to it and all the zone information are repeated at the main panel
M9900-PC-R5 The PC based user interface running on MS windows is used to display all device & zone information & floor plans on the screen.
M9900-Link-R6 The RS232 linking is provided for communicating with other building services system.
M9900-Mimic-R2 The multi-colour mimic panel consists of all floor plans and section of the building on perspex sheet, the LEDs on mimic floor plans will indicate the location of each fire zone.
M9900-LCD-R3 The LCD based Repeater is used to indicate device & zone information on the LCD display.
M9900-SFAP-R4 The sub-panel (Sub Fire Alarm Panel) can be part of main system, but located away from the main panel, it has the addressable devices connected to it and all the zone information are repeated at the main panel
M9900-PC-R5 The PC based user interface running on MS windows is used to display all device & zone information & floor plans on the screen.
M9900-Link-R6 The RS232 linking is provided for communicating with other building services system.
Brand | Mictron |
Model | 9900 |
Part Number | AXP-M9900 |
Input Power | 240VAC 50Hz |
Power Consumption | 24V DC 150mA (exclude loop power) |
Operating Temperature | 0ºC - 45ºC |
Humidity | Max 95% (non-condensation) |
Panel Construction | Mild steel |
Panel Thickness | 1.5mm thickness |
Finishing | Epoxy powder coated paint |
Colour | Light gray or red |
Dimension | 720mm (W) x 430mm (H) x 150mm (D) |
Weight | 18.6kg (exclude battery) |
Testing Standard | MS1745 Part2 : 2004 EN 54 Part2 : 2004 |
Test Report | 2014EEB0449, SIRIM |
Mictron 900 Multiplex System
Mictron 900 is a Multiplex Fire Alarm System, also known as "semi addressable" system. A standard Mictron 900 system consists of 2 buses. Each bus can interface up to 16 RPPU
The Central controller gather all information from the remote RPPU and process into visual and audio signals. The visual signals consist of LED display indicating locations of fire zones and indications. A graphical mimic will also display all the fire zones. The audio signal will alert security personnel of the occurrence of a fire situation.
The operator keyboard allows security personnel to perform the necessary steps as to disable or reset a fire zone.
The Central controller gather all information from the remote RPPU and process into visual and audio signals. The visual signals consist of LED display indicating locations of fire zones and indications. A graphical mimic will also display all the fire zones. The audio signal will alert security personnel of the occurrence of a fire situation.
The operator keyboard allows security personnel to perform the necessary steps as to disable or reset a fire zone.
Features :
- From 20 to 1000 zones
- With full zone & status LED display
- Compatible with all conventional devices
- Design for easy user operation
- Built-in 10A power supply/charger
There are 2 types of RPPU :
RPPU-32 Completed with 32 inputs, 3 bells/siren & 9 tripping outputs.
RPPU-12 Completed with 12 inputs, 2 bells/siren & 2 tripping outputs
Optional Sub-System
M900-LED-R1 The LED based Repeater is part of the main system, the LED will indicate the alarm, fault & disabled status of the zone, as well as non-urgent point such as pump status.
M900-Mimic-R2 The multi-colour mimic panel consists of all floor plans and section of the building on perspex sheet, the LEDs on mimic floor plans will indicate the location of each fire zone.
M900-REP-R3 The Repeater can be just a LCD/keyboard panel, or combination of LCD/keyboard with zone display panels.
M900-SFAP-R4 The sub-panel (Sub Fire Alarm Panel) can be part of main system, but located away from the main panel, it has the RPPU connected to it and all the zone information are repeated at the main panel
M900-PC-R5 The PC based user interface running on MS windows is used to display all zones information & floor plans on screen.
M900-Link-R6 The RS232 linking is provided for communicating with other building services system.
M900-Mimic-R2 The multi-colour mimic panel consists of all floor plans and section of the building on perspex sheet, the LEDs on mimic floor plans will indicate the location of each fire zone.
M900-REP-R3 The Repeater can be just a LCD/keyboard panel, or combination of LCD/keyboard with zone display panels.
M900-SFAP-R4 The sub-panel (Sub Fire Alarm Panel) can be part of main system, but located away from the main panel, it has the RPPU connected to it and all the zone information are repeated at the main panel
M900-PC-R5 The PC based user interface running on MS windows is used to display all zones information & floor plans on screen.
M900-Link-R6 The RS232 linking is provided for communicating with other building services system.
Brand | Mictron |
Model | 900 |
Part Number | AXP-M900 |
Microprocessor | Freescale MC9S12 & Rabbitcore 2000 |
Memory | 512Kb Flash & 64Kb RAM |
Ports | 2 RS232 & 2 Multidrop RS485 & 2 parallel |
Fire Brigade Link | Volt - free contact |
Input Power | 240VAC 50Hz |
Power Consumption | 24V DC 150mA (exclude RPPU power) |
Operating Temperature | 0ºC - 45ºC |
Humidity | Max 95% (non-condensation) |
Panel Construction | Mild steel |
Panel Thickness | 1.6mm thickness |
Finishing | Epoxy powder coated paint |
Colour | Red or Signal Red |
Dimension | 600 (W) x 530 (H) x 180 (D) |
Weight | 30kg (inclusive of 2 x 12V battery) |
Testing Standard | MS1745 Part2 : 2004 EN 54 Part2 : 2004 |
Test Report | 2014EEB0212, SIRIM |
C-9SL Conventional Optical Smoke Detector
- Dual LED alarm indicators for 360º viewing angle, LED flashing in standby mode.
- Advance sensor logic circuit with analog convector for smoke level discrimination algorithms
- Unique sensing chamber for smoke detection, with wire mesh for protection against dirt, dust and flying insects
AX-9HL ROR & FT Heat Detector
- Unique ALARM/RESET test tool for easy maintenance.
- Mounting back box with wire entry hole suitable for flush or surface mounting
- Optional protective clear plastic cover for double action alarm activation.
C-9BL Conventional Bell
- Unique swinging mechanism to prevent jamming
- High quality steel dome generates clear & loud sound.
- Low power DC motor with gear driven hitting rings.
SMOKE DETECTOR | HEAT DETECTOR | |
Brand | Mictron | Mictron |
Model | Series C | Series C |
Type | Photoelectric | ROR & Fixed temperature |
Part Number | C-9SL | C-9HL |
Rated Voltage | 24V DC | 24V DC |
Operating Voltage | 12-35V DC | 12-35V DC |
Standby | 100uA | 55uA |
Current | 70mA | 50mA |
Alarm Current (max) | 80mA | 80mA |
Permissible Current (max) | - | 57ºC |
Alarm Fixed Temperature | - | Thermistor |
Temperature Source | Infrared LED | - |
Light | 80m² at 6m height | 30m² at 6m height |
Source | IP42 | IP42 |
Coverage Area | -10 to +50ºC | -10 to +50ºC |
IP Rating | 95% RH(Non condensing) | 95% RH(Non condensing) |
Temperature Range | 15mA with diode gate | 15mA with diode gate |
Operating Humidity | 130g with base | 160g with base |
Remote Output | ABS | ABS |
Weight | 100mm x 46mm with base | 100mm x 46mm with base |
Color | White | White |
Dimension | EN 54-7, DIFT | EN 54-5, DIFT |
Approved Standard Certificate Number | 0845-CPD-232.1618 | 0845-CPD-232.1617 |
Test | 2014EEB0449 | Humidity |
Test | 2014EEB0449 | Humidity |
BREAK GLASS | ALARM BELL | |
Brand | Mictron | Mictron |
Model | Series C | Series C |
Type | Non resettable | DC Motor Bell |
Part Number | C-9BG | C-9BL |
Operating Voltage | 17-30V DC | 20-28V DC |
Alarm Current (max) | 20mA | 30mA |
Alarm Resistance Sound Output | 470 ohms | - |
Temperature Range | -20 to +70ºC | -20 to +60ºC |
Operating Humidity | 95% RH (Non condensing) | 90% RH (Non condensing) |
Weight | 153g (with base) | 764gm |
Material | ABS | High Quality Steel |
Dimension | 88mm x 88mm x 59mm | 150mm (Dia) x 56mm |
Colour | Signal Red | Signal Red |
Approved Standard | EN54-11, MS1745-11 | EN554-3, MS1745-3 |
Test Report | 2008EL0517, SIRIM | 2008EL0094, SIRIM |
Countries
We have customers from all over the world!
Malaysia
Singapore
China (Hong Kong)
US
UK
Japan
South Africa
India
UAE
Qatar
Iran
Iraq
Uzbekistan
Jordan
Denmark
Bulgaria
Panama
Nigeria
Morocco
Egypt